China Copeland Compressor Air Cooled Modular Chiller Cooling and Heating with CE Cert arb air compressor

Merchandise Description

Copeland Compressor Air Cooled Modular Chiller Cooling and Heating with Ce Cert
Cooling Potential sixty kW ~ 260 kW

Product Description

Attributes
The master module can operate independently or jointly with up to sixteen slave modules.

Models with V type heat exchanger: panels, frame and base are produced from galvanized metal safeguarded with polyester powder painting to make sure total resistance to atmospheric agents.

3-phase scroll type compressor, with created-in thermal overload minimize-out and crankcase heater, mounted on rubber vibration dampers.

External rotor kind axial enthusiasts, equipped with 3 period direct push motors, reduced noise 8 poles, security amount IP54, presented with a protective outlet grille.

Evaporator built with high performance Shell and tube type warmth exchanger, manufacturing unit insulated with flexible near cell content. 

Condenser created with seamless copper tubes mechanically expanded into blue hydrophilic aluminum fins.

Refrigerant circuit comprehensive with cost valves, filter drier, sight glass, gas-liquid separator, thermostatic enlargement valve, large & low force switch. The warmth pump device is finished also with 4-way valve, liquid receiver and 1 way valve.

Hydraulic circuit created with galvanized pipe, total with h2o discharge link for tube in tube heat exchanger and flange sort hydraulic connectors in 2 directions straightforward for connections from the two sides of the units.

Electric panel consist of: compressor contactor, fan motor contactor, compressor defense breaker, fan defense breaker, phase sequence relay and microprocessor with perform screen (exhibit only for grasp/packaged unit)

Computerized operation substantially lowering upkeep cost many thanks to reputable microprocessor method. 

OPTIONAL 

Paddle movement switch
Metallic filter for hydraulic circuit
Drinking water pump
Rubber antivibration mounting.
Heat restoration features

Complex Information

Model  AW   sixty one hundred one hundred thirty 200 260
Cooling potential* kW 65 ninety seven.five one hundred thirty 195 260
Cooling energy input kW twenty.eight 31.four forty two.one 63.6 eighty four.two
Heating ability** kW sixty eight 102 136 204 272
Heating power input kW twenty.2 30.six forty one 61.two 82
Max Enter Energy kW 24 35.seven forty seven.7 seventy one.4 ninety five.4
Max Enter existing A 50 74 ninety seven 148 194
Cooling Working Present A 46 68 89 136 178
Start-Up Recent A 167 187 206 374 412
Compressor
Power offer / 380/3/50
Brand/Sort / Daikin/Scroll
Refrigerant / R410a
Qty/refrigerant circuit Nr. two three 4 six 8
Cooling energy enter* kW two*9.4 three*9.sixty three 4*9.77 6*9.63 eight*9.seventy seven
Heating power enter** kW two*9.one three*9.36 4*9.5 6*9.36 8*9.five
Energy adjustment % 0- 
Axial supporter
Quantity Nr. two 2 two four four
Power input kW two 2.five three 5 6
Airflow m3/h 24000 36000 48000 72000 96000
Evaporator
Type / Shell and tube heat exchanger
  Water movement when cooling m3/h eleven.2 sixteen.8 22.four 33.six forty four.8
  Water flow when heating m3/h 11.seven seventeen.six 23.four 35.1 46.eight
  Water aspect force fall *** kPa forty six 52 55 52 fifty five
 Water link dimension DN fifty 50
 
65 2×50 2×65
Sounds stage***   dB(A) 70 72 seventy two 74 seventy five
Proportions  
V variety coil Size mm 2000 2207 2207 2207 2207
Width mm 1060 1300 1300 2207 2207
Height mm 1957 2076 2076 2096 2096
Net weight   kg 620 1060 1120 2160 2280
Operating excess weight   kg 635 1090 1155 2220 2350

*Ambient temperature 35ºC evaporator water in/out twelve/7 ºC
** Ambient temperature DB 7 ºC, WB 6 ºC condenser h2o in/out temperature forty/forty five ºC
*** In the nominal h2o movement problem the pressure drop is in between this range.
**** Seem stress measured at a distance of 1 m and a height of 1.5 m above the floor in a dear subject.

Product Photographs

Contruction Photograph

Straightforward Creation Procedure

Basic Overseas Tasks

Our Factory and Certification

Make contact with Information

 
 
 
———————————————————————————-
HangZhou CZPT AIR CONDITIONING CO.,LTD
 
Web site: HangZhouamrtaac

 

US $4,000-16,570
/ Piece
|
1 Piece

(Min. Order)

###

Type: Air-Cooled
Cooling Method: Air-cooled
Unit Structure: Integral
Selected Voltage: 50Hz/60Hz
Compressor Number: 2-4
Noise Level: Low

###

Customization:

###

Model  AW   60 100 130 200 260
Cooling capacity* kW 65 97.5 130 195 260
Cooling power input kW 20.8 31.4 42.1 63.6 84.2
Heating capacity** kW 68 102 136 204 272
Heating power input kW 20.2 30.6 41 61.2 82
Max Input Power kW 24 35.7 47.7 71.4 95.4
Max Input current A 50 74 97 148 194
Cooling Running Current A 46 68 89 136 178
Start-Up Current A 167 187 206 374 412
Compressor
Power supply / 380/3/50
Brand/Type / Daikin/Scroll
Refrigerant / R410a
Qty/refrigerant circuit Nr. 2 3 4 6 8
Cooling power input* kW 2*9.4 3*9.63 4*9.77 6*9.63 8*9.77
Heating power input** kW 2*9.1 3*9.36 4*9.5 6*9.36 8*9.5
Energy adjustment % 0-25-50-75-100 
Axial fan
Quantity Nr. 2 2 2 4 4
Power input kW 2 2.5 3 5 6
Airflow m3/h 24000 36000 48000 72000 96000
Evaporator
Type / Shell and tube heat exchanger
  Water flow when cooling m3/h 11.2 16.8 22.4 33.6 44.8
  Water flow when heating m3/h 11.7 17.6 23.4 35.1 46.8
  Water side pressure drop *** kPa 46 52 55 52 55
 Water connection size DN 50 50
 
65 2×50 2×65
Noise level***   dB(A) 70 72 72 74 75
Dimensions  
V type coil Length mm 2000 2207 2207 2207 2207
Width mm 1060 1300 1300 2207 2207
Height mm 1957 2076 2076 2096 2096
Net weight   kg 620 1060 1120 2160 2280
Working weight   kg 635 1090 1155 2220 2350
US $4,000-16,570
/ Piece
|
1 Piece

(Min. Order)

###

Type: Air-Cooled
Cooling Method: Air-cooled
Unit Structure: Integral
Selected Voltage: 50Hz/60Hz
Compressor Number: 2-4
Noise Level: Low

###

Customization:

###

Model  AW   60 100 130 200 260
Cooling capacity* kW 65 97.5 130 195 260
Cooling power input kW 20.8 31.4 42.1 63.6 84.2
Heating capacity** kW 68 102 136 204 272
Heating power input kW 20.2 30.6 41 61.2 82
Max Input Power kW 24 35.7 47.7 71.4 95.4
Max Input current A 50 74 97 148 194
Cooling Running Current A 46 68 89 136 178
Start-Up Current A 167 187 206 374 412
Compressor
Power supply / 380/3/50
Brand/Type / Daikin/Scroll
Refrigerant / R410a
Qty/refrigerant circuit Nr. 2 3 4 6 8
Cooling power input* kW 2*9.4 3*9.63 4*9.77 6*9.63 8*9.77
Heating power input** kW 2*9.1 3*9.36 4*9.5 6*9.36 8*9.5
Energy adjustment % 0-25-50-75-100 
Axial fan
Quantity Nr. 2 2 2 4 4
Power input kW 2 2.5 3 5 6
Airflow m3/h 24000 36000 48000 72000 96000
Evaporator
Type / Shell and tube heat exchanger
  Water flow when cooling m3/h 11.2 16.8 22.4 33.6 44.8
  Water flow when heating m3/h 11.7 17.6 23.4 35.1 46.8
  Water side pressure drop *** kPa 46 52 55 52 55
 Water connection size DN 50 50
 
65 2×50 2×65
Noise level***   dB(A) 70 72 72 74 75
Dimensions  
V type coil Length mm 2000 2207 2207 2207 2207
Width mm 1060 1300 1300 2207 2207
Height mm 1957 2076 2076 2096 2096
Net weight   kg 620 1060 1120 2160 2280
Working weight   kg 635 1090 1155 2220 2350

what to see in an air compressor

If you need to buy an air compressor, you should know what to look for. The types of air compressors on the market are classified according to their CFM rating, safety devices, and pumps. There are several differences between lubricated and oil-free air compressors that you should know before buying. To better understand the difference between these types of air compressors, read on. This article will guide you through these differences.

Pump

If you are looking for a quality air compressor, you have come to the right place. A good air compressor pump will provide high pressure for anything from tires to boats and more. There are hundreds of different models to choose from, and the great thing about buying one from a Chinese manufacturer is that they have so many options. More importantly, Chinese manufacturers can customize air equipment such as air compressors at low prices.
A good quality air pump won’t break easily, but you’ll be able to use it for years. Choosing a high-quality pump will help you avoid many hassles on the road, such as unplanned downtime and installation costs. Plus, a pump from the same manufacturer as your air compressor is your best bet to ensure optimum performance. Listed below are some tips for finding a quality pump for your air compressor.
The air compressor is an important but unremarkable invention. Without them, our lives would be completely different. Without a pump, we can’t get hot water from central heating, nor can we get heat from the refrigerator. We can’t inflate bicycle tires, and we can’t refuel cars. Pumps are vital to all kinds of machines. So why is it important to choose the right product? The answer may surprise you.
Different types of pumps are used for different applications. Positive displacement pumps move a fixed volume of fluid and direct it to a drain. This design ensures constant flow at a constant speed regardless of discharge pressure. Centrifugal pumps work differently. The impeller accelerates the fluid, converting the input energy into kinetic energy. This type of pump is most commonly used in mines, air conditioning, industrial plants, and flood control.
air-compressor

safety equipment

There are several safety features you should check when using an air compressor. First, check the connection of the air filter to the air. If they come loose, parts may separate and cause injury. Another important safety feature is the shut-off valve. When working near compressed air, the shut-off valve should be within easy reach and visibility. Moving parts and other equipment must be protected with protective covers. Check safety valve and replace damaged parts.
Rupture discs are copper discs located on the air cooler. When the air pressure exceeds a certain limit, it bursts. Fusible plugs contain materials that melt at high temperatures. The compressor should have a lubricating oil pressure alarm and cut off the trip signal. If these two safety devices fail, the compressor should be stopped immediately. The rupture disc should be inspected at least weekly to ensure it does not rupture under pressure.
If the pressure level is too high, and overcurrent protection device cuts power to the motor. It also automatically shuts off the compressor when the hose ruptures or the air volume exceeds a preset level. The device should be installed on the air compressor to prevent accidents. Its job is to protect the operator from harm. If employees do not follow these safety measures, they may cause equipment damage.
To ensure safety when operating the air compressor, safety glasses and gloves should be worn. Pressurized air can cause eye injury, and crash goggles can provide a barrier to prevent this. Additionally, the self-retracting cord prevents trip hazards and reinforces excess cord. You should also keep your hands and body away from the air nozzle. This will prevent you from being sprayed with compressed air.

CFM Rating

An air compressor’s PSI and CFM ratings indicate the pressure and volume it can deliver. PSI stands for pounds per square inch and measures the force and pressure contained in one square inch of air. These two indicators are equally important when choosing an air compressor. If you need a lot of compressed air for a specific application, you will need a higher psi compressor. Likewise, if you are using compressed air in a smaller application, a low cfm compressor will not provide enough power to meet your needs.
When comparing different air compressors, be sure to pay close attention to horsepower and CFM ratings. While compressor power is essential for some tasks, it is not the most important aspect. The CFM rating of an air compressor will determine how big a project it can handle and how long it takes to charge. Make sure you understand the CFM and PSI ratings of your future compressors, as not knowing these important statistics can frustrate you and drive up costs.
In general, it is best to choose an air compressor with a CFM rating higher than the size of the air tool. This will ensure that the air compressor has enough pressure to work multiple tools efficiently at the same time. While smaller CFM ratings may be sufficient for smaller projects, larger tools such as drills require a lot of air. Therefore, the higher the CFM, the larger and more powerful the tool.
Once you understand the CFM of an air compressor, you can start looking for the right tool. You can check the CFM rating of your air compressor online by commenting below. If you’re not sure about the size of your air tool, you can always buy a second air compressor. This is a great way to double the CFM of your air compressor! You’ll have more air to do more work, and your compressor will last longer.
air-compressor

Lack of oil and lubrication

Oil-free air compressors have a smaller footprint and require less maintenance than oil-lubricated air compressors. Although oil-lubricated air compressors are more expensive and heavier than oil-free air compressors, they are also ideal for stationary use. The benefits of oil-free air compressors include greater durability and lower maintenance costs. The advantages and disadvantages of each type are discussed below.
Oil-free air compressors are generally quieter than oil-lubricated air compressors. However, you may still experience some noise while using it. To avoid this, you should choose a quiet intake compressor. However, if you work next to a noisy compressor, you should buy a muffler, an aftermarket filter that reduces compressor noise.
If you want to use the air compressor for a long time, the oil-free model is not the right choice. Its Teflon coating wears off over time, especially at extreme temperatures. Additionally, oil-free air compressors have a large number of moving parts that require regular maintenance, while oil-filled air compressors are great for those who don’t want to invest in extra parts.
Another major difference between oil-free and oil-lubricated air compressors is lubrication. Oil-lubricated air compressors require regular lubrication whereas oil-free air compressors are pre-lubricated. They have fewer parts and are cheaper. Oil-free air compressors are lighter than oil-lubricated air compressors. In addition to being more affordable, oil-free air compressors are more powerful and durable.
While oil-filled air compressors are more efficient and durable, they generate a lot of heat. However, they are also more expensive and require regular oil changes. Furthermore, they are difficult to transport. They also need to be permanently installed. These air compressors are also not portable and require a fixed location. So, consider your needs before deciding which type is best for you. When you’re choosing an air compressor for your business, be sure to shop around.
air-compressor

noise level

If you are wondering what the noise level of an air compressor is, the answer depends on your specific equipment and working environment conditions. Typically, air compressors produce 40 to 90 decibels of noise. Although the lower the decibel level, the quieter the compressor will be. Larger, more powerful air compressors produce higher noise levels than their little brothers. But no matter how big the air compressors are, it’s a good idea to wear hearing protection while working around them.
When purchasing a new air compressor, the noise level of the air compressor should be considered. While this may seem like a small problem, there are actually a lot of variations on these noisy machines. The most common type of air compressor is the reciprocating piston pump. This model uses pistons similar to an engine to rotate inside a chamber. The piston moves quickly and traps air proportional to its size. Single-piston air compressors are generally noisier than twin-piston models, also known as twin cylinders.
But even if you have the proper equipment to protect your hearing, it’s still important to know the noise level of an air compressor. Even if the noise is not immediately dangerous, it can still cause temporary or permanent hearing loss. This condition is called noise-induced hearing loss, and an air compressor with a sound level of 80 or higher can cause permanent hearing damage. You can avoid potential damage to your hearing and prevent accidents by simply paying attention to the noise level of your air compressor.
Air compressors are inherently noisy, but if you take steps to reduce their noise levels, you can minimize disruption to neighbors and co-workers. For example, installing a sound enclosure in your work area can prevent your air compressor from making as much noise as before. Depending on your workspace, you can also try installing a long air hose, which will reduce sound levels by up to 25%.
China Copeland Compressor Air Cooled Modular Chiller Cooling and Heating with CE Cert     arb air compressorChina Copeland Compressor Air Cooled Modular Chiller Cooling and Heating with CE Cert     arb air compressor
editor by czh 2023-01-20